Stent-edge vasospasm after bare metal stent implantation: a case report and review of the literature
PDF
Cite
Share
Request
Case Report
P: 174-176
September 2009

Stent-edge vasospasm after bare metal stent implantation: a case report and review of the literature

Gulhane Med J 2009;51(3):174-176
1. Department of Cardiology, Gulhane Military Medical Faculty
2. Department of Cardiology, Sarıkamış Army District Hospital
No information available.
No information available
Received Date: 10.10.2007
Accepted Date: 31.03.2008
PDF
Cite
Share
Request

ABSTRACT

It has been shown that coronary stenting is associated with long term abnormal endothelial dysfunction causing pronounced vasoconstrictor response to different stimuli. Stent edge vasospasm after coronary stenting may mimic stent edge restenosis, which may lead to an unnecessary intervention. This case report reemphasizes the importance of recognizing coronary vasospasm after stent implantation which may otherwise mislead the interventional cardiologist.